Healthcare Professionals
Protégé™ EverFlex™ Self-expanding Peripheral and Biliary Stent
Peripheral and Biliary Stenting
You just clicked a link to go to another website. If you continue, you may go to a site run by someone else.
We do not review or control the content on non-Medtronic sites, and we are not responsible for any business dealings or transactions you have there. Your use of the other site is subject to the terms of use and privacy statement on that site.
It is possible that some of the products on the other site are not approved in your region or country.
Your browser is out of date
With an updated browser, you will have a better Medtronic website experience. Update my browser now.
The content of this website is exclusively reserved for Healthcare Professionals in countries with applicable health authority product registrations, except those practicing in France as some of the content is not in compliance with the French Advertising law N°2011-2012 dated 29th December 2011, article 34.
Click “OK” to confirm you are a Healthcare Professional.
Healthcare Professionals
Protégé™ EverFlex™ Self-expanding Peripheral and Biliary Stent
Peripheral and Biliary Stenting
Choose the Protégé™ EverFlex™ Self-Expanding Peripheral Stent System for its combined benefits of durability and deployment accuracy — all in a broad range of sizes. Treat lesions in either the SFA, proximal popliteal, subclavian, common and/or external iliac arteries or in the biliary system with confidence, knowing that the DURABILITY trial series demonstrated safety and efficacy of the EverFlex™ Stent in complex patient populations.
The stent is indicated for use in the following types of occlusions or lesions:
Stenting is intended to improve and maintain the artery luminal diameter.
The stent is indicated as a palliative treatment of malignant neoplasms in the biliary tree.
All indications related to the Protégé™ EverFlex™ Self-expanding Peripheral and Biliary Stent are not approved globally, please refer to the complete Instructions for Use manual for the indication for Use approved in your geography.
The EverFlex™ Self-expanding Peripheral Stent is deliverable through a 6 F catheter. Its broad size matrix (20 mm – 200 mm) allows physicians to choose the most appropriate single-stent fit.
Pin-Pull Delivery System
The stent is mounted on a traditional "pin-pull" style delivery system.
Design of EverFlex™ Self-expanding Peripheral Stent
Instructions for Use
Find this technical manual in the product labeling supplied with each device.
Catheter Length | Stent Size | Compatibility | ||||
---|---|---|---|---|---|---|
|
Reference Number 120 cm |
Diameter (mm) |
Length (mm) |
Recommended Introducer Sheath (F) |
Guidewire (in) |
Recommended Lumen Size mm) |
PRP35-05-020-080 | PRP35-05-020-120 | 5 | 20 | 6 | 0.035 | 3.5-4.5 |
PRP35-05-030-080 | PRP35-05-030-120 | 5 | 30 | 6 | 0.035 | 3.5-4.5 |
PRP35-05-040-080 | PRP35-05-040-120 | 5 | 40 | 6 | 0.035 | 3.5-4.5 |
PRP35-05-060-080 | PRP35-05-060-120 | 5 | 60 | 6 | 0.035 | 3.5-4.5 |
PRP35-05-080-080 | PRP35-05-080-120 | 5 | 80 | 6 | 0.035 | 3.5-4.5 |
PRP35-05-100-080 | PRP35-05-100-120 | 5 | 100 | 6 | 0.035 | 3.5-4.5 |
PRP35-05-120-080 | PRP35-05-120-120 | 5 | 120 | 6 | 0.035 | 3.5-4.5 |
PRP35-05-150-080 | PRP35-05-150-120 | 5 | 150 | 6 | 0.035 | 4.5-5.5 |
PRP35-06-020-080 | PRP35-06-020-120 | 6 | 20 | 6 | 0.035 | 4.5-5.5 |
PRP35-06-030-080 | PRP35-06-030-120 | 6 | 30 | 6 | 0.035 | 4.5-5.5 |
PRP35-06-040-080 | PRP35-06-040-120 | 6 | 40 | 6 | 0.035 | 4.5-5.5 |
PRP35-06-060-080 | PRP35-06-060-120 | 6 | 60 | 6 | 0.035 | 4.5-5.5 |
PRP35-06-080-080 | PRP35-06-080-120 | 6 | 80 | 6 | 0.035 | 4.5-5.5 |
PRP35-06-100-080 | PRP35-06-100-120 | 6 | 100 | 6 | 0.035 | 4.5-5.5 |
PRP35-06-120-080 | PRP35-06-120-120 | 6 | 120 | 6 | 0.035 | 4.5-5.5 |
PRP35-06-150-080 | PRP35-06-150-120 | 6 | 150 | 6 | 0.035 | 4.5-5.5 |
N/A | PRP35DR-06-200-120 | 6 | 200 | 6 | 0.035 | 4.5-5.5 |
PRP35-07-020-080 | PRP35-07-020-120 | 7 | 20 | 6 | 0.035 | 5.5-6.5 |
PRP35-07-030-080 | PRP35-07-030-120 | 7 | 30 | 6 | 0.035 | 5.5-6.5 |
PRP35-07-040-080 | PRP35-07-040-120 | 7 | 40 | 6 | 0.035 | 5.5-6.5 |
PRP35-07-060-080 | PRP35-07-060-120 | 7 | 60 | 6 | 0.035 | 5.5-6.5 |
PRP35-07-080-080 | PRP35-07-080-120 | 7 | 80 | 6 | 0.035 | 5.5-6.5 |
PRP35-07-100-080 | PRP35-07-100-120 | 7 | 100 | 6 | 0.035 | 5.5-6.5 |
PRP35-07-120-080 | PRP35-07-120-120 | 7 | 120 | 6 | 0.035 | 5.5-6.5 |
PRP35-07-150-080 | PRP35-07-150-120 | 7 | 150 | 6 | 0.035 | 5.5-6.5 |
N/A | PRP35DR-07-200-120 | 7 | 200 | 6 | 0.035 | 5.5-6.5 |
PRP35-08-020-080 | PRP35-08-020-120 | 8 | 20 | 6 | 0.035 | 6.5-7.5 |
PRP35-08-030-080 | PRP35-08-030-120 | 8 | 30 | 6 | 0.035 | 6.5-7.5 |
PRP35-08-040-080 | PRP35-08-040-120 | 8 | 40 | 6 | 0.035 | 6.5-7.5 |
PRP35-08-060-080 | PRP35-08-060-120 | 8 | 60 | 6 | 0.035 | 6.5-7.5 |
PRP35-08-080-080 | PRP35-08-080-120 | 8 | 80 | 6 | 0.035 | 6.5-7.5 |
PRP35-08-100-080 | PRP35-08-100-120 | 8 | 100 | 6 | 0.035 | 6.5-7.5 |
PRP35-08-120-080 | PRP35-08-120-120 | 8 | 120 | 6 | 0.035 | 6.5-7.5 |
PRP35-08-150-080 | PRP35-08-150-120 | 8 | 150 | 6 | 0.035 | 6.5-7.5 |
N/A | PRPDR35-08-200-120 | 8 | 200 | 6 | 0.035 | 6.5-7.5 |
See product catalogue for complete, detailed product information.