The content of this website is exclusively reserved for Healthcare Professionals in countries with applicable health authority product registrations, except those practicing in France as some of the content is not in compliance with the French Advertising law N°2011-2012 dated 29th December 2011, article 34.
Click “OK” to confirm you are a Healthcare Professional.
Engineered for efficiency
The PulseSelect™ PFA System is setting a new standard in safety for paroxysmal and persistent atrial fibrillation ablation supported by 15 years of robust pre-clinical and clinical evidence. The PulseSelect™ PFA System offers a differentiated approach to pulsed field ablation that can be implemented across workflows, driving safe, effective, and efficient procedures.
Engineered with differentiated safety features from 15 years of PFA research and backed by the results of the safest IDE AF ablation trials to date.
Rapid, effective PVI through consistent and predictable energy delivery and catheter maneuverability.
Seamless transition to PFA with freedom to adapt to your preferred workflow.
PulseSelect Solutions Animation - (03:33)
Video showing PulseSelect pulsed field ablation (PFA) product.
More information (see more)
Less information (see less)
Differentiated system safety features developed over 15 years of PFA research
1 - Test pulse for proximity detection to phrenic nerve
2 - R-wave gating for synchronisation of energy delivery
3 - Automatic overcurrent detection for safe energy delivery
4 - 9 electrodes built to sense, ablate and pace
5 - 25mm diameter loop
6 - 9Fr shaft with bidirectional steering
Fixed electrode spacing
to produce a reliable field for predictable and consistent contiguous energy delivery
20-degree forward tilt
to ensure more consistent uniform tissue contact
Steering therapy with confidence
7 - Braided bidirectional shaft design provides catheter support and resistance to kinking
8 - Smooth sheath-dilator transition with transseptal crossing indication
9 - Robust adjustment knob and rounded handle
10 - Two tip length options to enable alignment with RIPV in difficult anatomies
PULSED AF evaluated the safety and effectiveness of the PulseSelect™ PFA system for the treatment of patients with paroxysmal and persistent atrial fibrillation and resulted in one of the lowest safety event rates of any AF ablation IDE trial to date.
Verma A, Haines DE, Boersma LV, et al. Pulsed Field Ablation for the Treatment of Atrial Fibrillation: PULSED AF Pivotal Trial. Circulation. May 9, 2023; 147(19): 1422-1432.
Product is CE marked according to law.