Healthcare Professionals

MYOtherm XP

Cardioplegia Delivery System

MYOtherm XP Cardioplegia Delivery System

The Medtronic MYOtherm XP® Cardioplegia Delivery System was specifically designed to effectively handle air, in a low-prime design, while providing fast responses through efficient heat transfer.

Overview

Cardioplegia plays a critical role keeping the heart protected and arrested during cardiopulmonary bypass by maintaining a desired ratio of blood and cardioplegic solution at a prescribed temperature.

The Medtronic MYOtherm XP® Cardioplegia Delivery System was specifically designed to effectively handle air, in a low-prime design, while providing fast responses through efficient heat transfer.

The MYOtherm XP System has advantages that set it apart from other cardioplegia products.

  • Unique design of the blood inlet port promotes even blood flow over the stainless-steel bellows for single-pass heat exchange
  • Heat Exchanger diverter wall traps air as it directs the flow of blood from the bellows to the top of the outlet chamber
  • “Bottom-in, Bottom-out” design provides fast response times over a range of flow rates
  • Temperature-monitoring site (TMA) in middle of the blood outlet for accurate temperature monitoring
  • 150-micron filter captures any air emboli and particulates as blood exits the outlet chamber
  • Pressure relief valve protects the heat exchanger from over-pressurisation
  • Available in Medtronic's custom tubing packs

Now available with Cortiva™ BioActive Surface for your tip-to-tip needs.

Ordering Info

MYOtherm XP® Blood Cardioplegia Delivery Systems
Order Number Description # of Units
XP41 MYOtherm XP Cardioplegia Delivery System (4:1 Blood to Crystalloid) 4 per case
XP41B MYOtherm XP Cardioplegia Delivery System (4:1 Blood to Crystalloid) with Bridge between Blood and Crystalloid Lines 4 per case
XPD2 MYOtherm XP® Delivery Line Single Table Delivery System 4 per case
MYOtherm XP Cardioplegia Delivery System with Cortiva™ BioActive Surface
CBXP41 MYOtherm XP Cardioplegia Delivery System with Cortiva™ BioActive Surface (4:1 Blood to Crystalloid) 4 per case
CBXP41B MYOtherm XP Cardioplegia Delivery System with Cortiva™ BioActive Surface (4:1 Blood to Crystalloid) with Bridge between Blood and Crystalloid Lines 4 per case
Cardioplegia Holders and Accessories
08182 MYOtherm XP Cardioplegia Holder  
08183 MYOtherm XP Cardioplegia Holder—small (fits ½" pole)  
61399400072 Thermistor Probe (TP) for MYOtherm  
5901 Cardioplegia Bucket Holder