Your browser is out of date

With an updated browser, you will have a better Medtronic website experience. Update my browser now.

×

Skip to main content

Healthcare Professionals

Amphirion™ Deep PTA Catheter

Percutaneous Transluminal Angioplasty

Overview

Reach for the Amphirion™ Deep PTA Catheter when your works calls for a PTA catheter that is highly conformable and flexible — that can move through tortuous anatomy and then cross lesions easily. Available in a broad size offering — in balloons up to 210 mm in length and shafts 120 and 150 cm in length — these balloons are ideally suited for treating long, diffuse, and distal lesions below the ankle and into the foot.

Indications

The Amphirion™ Deep PTA Catheter is specially designed for the percutaneous transluminal angioplasty of vascular districts as femoral artery and below the knee vessels with a reference diameter equal or larger than selected balloon sizes. 

Product Details

The Amphirion™ Deep PTA Catheter is ideally suited for work below the ankle.  

  • Great lesion crossing capability, with its low balloon crossing profile
  • High conformability and flexibility, with the ability to move through tortuous anatomy and track to distal lesions
  • Broad size offering (balloons up to 210 mm in length), with long shaft design (120 and 150 cm lengths) to reach distal lesions
  • Tapered balloon to respect arterial anatomy (diameter reduction from proximal to distal end is 0.5 mm for the 210 mm balloon length)
Amphirion Deep Crossability Chart

Amphirion™ Deep PTA Catheter Crossability
The low balloon crossing profile enhances lesion crossing.

Amphirion Deep Trackability Chart

Amphirion™ Deep PTA Catheter Trackability
Amphirion™ Deep PTA Catheter is conformable and flexible in construction for easy tracking through tortuous anatomy.

Data on file at Medtronic with reference CP134BT01R.

*

Third party brands are trademarks of their respective owners.

Manuals and Technical Guides

Instructions for Use

Find this technical manual in the product labeling supplied with each device.

Model Specifications

 
Type Specification
Catheter Design Over the Wire (OTW)
Balloon Material Flexitec™ Ultra
Balloon Coating Balloon and distal shaft LFC hydrophilic
Shaft Diameter Proximal 3.9 F
Middle 3.3 F
Distal 2.8 /2.6 F
Max. Recommended Guidewire 0.014"
Inducer Sheath Compatibility 4 F
NBP 7 bar

ORDERING INFORMATION

Reference Number

 

Balloon
Diameter
(mm)
Balloon
Length
(mm)
Shaft
Length
(cm)
Recommended
Introducer
Sheath
(F)
AMD 020 040 002 2.0 40 120 4
AMD 020 040 152 2.0 40 150 4
AMD 020 080 002 2.0 80 120 4
AMD 020 080 152 2.0 80 150 4
AMD 020 120 002 2.0 120 120 4
AMD 020 120 152 2.0 120 150 4
AMD 020 150 002 2.0 150 120 4
AMD 020 150 152 2.0 150 150 4
AMD 025 040 002 2.5 40 120 4
AMD 025 040 152 2.5 40 150 4
AMD 025 080 002 2.5 80 120 4
AMD 025 080 152 2.5 80 150 4
AMD 025 120 002 2.5 120 120 4
AMD 025 120 152 2.5 120 150 4
AMD 025 150 002 2.5 150 120 4
AMD 025 150 152 2.5 150 150 4
AMD 030 040 002 3.0 40 120 4
AMD 030 040 152 3.0 40 150 4
AMD 030 080 002 3.0 80 120 4
AMD 030 080 152 3.0 80 150 4
AMD 030 120 002 3.0 120 120 4
AMD 030 120 152 3.0 120 150 4
AMD 030 150 002 3.0 150 120 4
AMD 030 150 152 3.0 150 150 4
AMD 035 040 002 3.5 40 120 4
AMD 035 040 152 3.5 40 150 4
AMD 035 080 002 3.5 80 120 4
AMD 035 080 152 3.5 80 150 4
AMD 035 120 002 3.5 120 120 4
AMD 035 120 152 3.5 120 150 4
AMD 035 150 002 3.5 150 120 4
AMD 035 150 152 3.5 150 150 4
AMD 040 040 002 4.0 40 120 4
AMD 040 040 152 4.0 40 150 4
AMD 040 080 002 4.0 80 120 4
AMD 040 080 152 4.0 80 150 4
AMD 040 120 002 4.0 120 120 4
AMD 040 120 152 4.0 120 150 4
AMD 040 150 002 4.0 150 120 4
AMD 040 150 152 4.0 150 150 4
AMD 225 210 002 2.0/2.5 210 120 4
AMD 225 210 152 2.0/2.5 210 150 4
AMD 253 210 002 2.5/3.0 210 120 4
AMD 253 210 152 2.5/3.0 210 150 4
AMD 335 210 002 3.0/3.5 210 120 4
AMD 335 210 152 3.0/3.5 210 150 4
AMD 354 210 002 3.5/4.0 210 120 4
AMD 354 210 152 3.5/4.0 210 150 4

 

See product catalogue for complete, detailed product information.

This page may include information about products that may not be available in your region or country. Please consult the approved indications for use. Content on specific Medtronic products is not intended for users in markets that do not have authorisation for use.