Your browser is out of date

With an updated browser, you will have a better Medtronic website experience. Update my browser now.

×

Skip to main content

Healthcare Professionals

NanoCross Elite 0.014" OTW PTA Balloon Catheter

Percutaneous Transluminal Angioplasty

Overview

Approach tight lesions with a low-profile, tapered tip when you use the NanoCross™ Elite 0.014" OTW PTA balloon catheter. The catheter's robust shaft design makes it easier to access, reach and treat distal lesions in the lower leg.

Indications

The NanoCross Elite 0.014” Over-the-Wire PTA Balloon Dilatation Catheter is intended to dilate stenoses in the iliac, femoral, ilio-femoral, popliteal, infra-popliteal, and renal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for stent post-dilatation in the peripheral vasculature.

Product Details

  • NanoCross Elite 0.014' OTW PTA balloon catheter has the pushability to take you deeper into the anatomy and across difficult lesions.
  • Seamless design results in efficient energy transfer with no hang-up points.
  • Robust shaft design offers buckle‑resistant pushability and delivery across the length of the catheter.
  • Smooth, tapered tip offers better control to easily navigate turns and tortuosity.
  • Low crossing profile enables successful crossing of lesions.
  • Tighter pleat fold reduces the crossing profile for easier access to smaller, tighter, more distal regions.

Energy Transfer

Energy Transfer Comparison

The NanoCross Elite PTA balloon (top) transfers energy efficiently through a seamless design with no hang-up points. A typical PTA balloon (bottom) has hang-up points that may cause energy dispersal.

Design of NanoCross Elite PTA Balloon

Design of NanoCross Elite PTA Balloon
  1. Robust shaft design for kink-resistant pushability and delivery across the length of the catheter.
  2. Smooth, tapered tip offers better control to easily navigate turns and tortuosity.
  3. Low crossing profile enables successful crossing of tandem lesions.
  4. Tighter pleat fold reduces the crossing profile for easier access to smaller, tighter, distal regions.

Manuals and Technical Guides

Instructions for Use

Find this technical manual in the product labeling supplied with each device.

ORDERING INFORMATION

Reference Number
90 cm Catheter
Length

Reference Number
150 cm Catheter
Length

Balloon
Diameter
(mm)

Balloon
Length
(mm)

Nominal
Pressure
(atm)

Rated
Burst
Pressure 
(atm) 

Recommended
Introducer
Sheath
(F)

AB14W015020090

AB14W015020150

1.5

20

 8

 14

 4

AB14W015040090

AB14W015040150

1.5

40

 8

 14

 4

AB14W020020090

AB14W020020150

2.0

20

 8

 14

 4

AB14W020040090

AB14W020040150

2.0

40

 8

 14

 4

AB14W020060090

AB14W020060150

2.0

60

 8

14

 4

AB14W020080090

AB14W020080150

2.0

80

 8

 14

 4

AB14W020100090

AB14W020100150

2.0

100

 8

 14

 4

AB14W020120090

AB14W020120150

2.0

120

 8

 14

 4

AB14W020150090

AB14W020150150

2.0

150

 8

 14

 4

AB14W020210090

AB14W020210150

2.0 (proximal) /
1.5 (distal)

210

 8

 14

 4

AB14W025020090

AB14W025020150

2.5

20

 8

 14

 4

AB14W025040090

AB14W025040150

2.5

40

 8

 14

 4

AB14W025060090

AB14W025060150

2.5

60

 8

 14

4

AB14W025080090

AB14W025080150

2.5

80

 8

 14

 4

AB14W025100090

AB14W025100150

2.5

100

 8

 14

 4

AB14W025120090

AB14W025120150

2.5

120

 8

 14

 4

AB14W025150090

AB14W025150150

2.5

150

 8

 14

 4

AB14W025210090

AB14W025210150

2.5 (proximal) /
2.0 (distal)

210

 8

 14

 4

AB14W030020090

AB14W030020150

3.0

20

8

 14

 4

AB14W030040090

AB14W030040150

3.0

40

8

14

4

AB14W030060090

AB14W030060150

3.0

60

 8

 14

 4

AB14W030080090

AB14W030080150

3.0

80

 8

 14

 4

AB14W030100090

AB14W030100150

3.0

100

 8

 14

 4

AB14W030120090

AB14W030120150

3.0

120

 8

 14

 4

AB14W030150090

AB14W030150150

3.0

150

 8

 14

 4

AB14W030210090

AB14W030210150

3.0 (proximal) /
2.5 (distal)

210

 8

 14

 4

AB14W035020090

AB14W035020150

3.5

20

 8

 14

 4

AB14W035040090

AB14W035040150

3.5

40

8

14

4

AB14W035060090

AB14W035060150

3.5

60

8

14

 4

AB14W035080090

AB14W035080150

3.5

80

8

14

4

AB14W035100090

AB14W035100150

3.5

100

8

14

4

AB14W035120090

AB14W035120150

3.5

120

8

14

4

AB14W035150090

AB14W035150150

3.5

150

8

14

4

AB14W035210090

AB14W035210150

3.5 (proximal) /
3.0 (distal)

210

8

14

4

AB14W040020090

AB14W040020150

4.0

20

8

14

4

AB14W040040090

AB14W040040150

4.0

40

8

14

4

AB14W040060090

AB14W040060150

4.0

60

8

14

4

AB14W040080090

AB14W040080150

4.0

80

8

14

4

AB14W040100090

AB14W040100150

4.0

100

8

14

4

AB14W040120090

AB14W040120150

4.0

120

8

14

4

AB14W040150090

AB14W040150150

4.0

150

8

14

4

AB14W040210090

AB14W040210150

4.0 (proximal) /
3.5 (distal)

210

8

14

4

AB14W050020090

AB14W050020150

5.0

20

8

14

5

AB14W050040090

AB14W050040150

5.0

40

8

14

5

AB14W050060090

AB14W050060150

5.0

60

8

14

5

AB14W050080090

AB14W050080150

5.0

80

8

14

5

AB14W050100090

AB14W050100150

5.0

100

8

14

5

AB14W050120090

AB14W050120150

5.0

120

8

14

5

AB14W050150090

AB14W050150150

5.0

150

8

14

5

AB14W050200090

AB14W050200150

5.0

200

8

14

5

AB14W060020090

AB14W060020150

6.0

20

8

14

5

AB14W060040090

AB14W060040150

6.0

40

8

14

5

AB14W060060090

AB14W060060150

6.0

60

8

14

5

AB14W060080090

AB14W060080150

6.0

80

8

14

5

AB14W060100090

AB14W060100150

6.0

100

8

14

5

AB14W060120090

AB14W060120150

6.0

120

8

14

5

AB14W060150090

AB14W060150150

6.0

150

8

14

5

AB14W060200090

AB14W060200150

6.0

200

8

14

6

 

See product catalogue for complete, detailed product information.