Pacific Xtreme PTA Balloon Catheter
Percutaneous Transluminal Angioplasty
You just clicked a link to go to another website. If you continue, you may go to a site run by someone else.
We do not review or control the content on non-Medtronic sites, and we are not responsible for any business dealings or transactions you have there. Your use of the other site is subject to the terms of use and privacy statement on that site.
It is possible that some of the products on the other site are not approved in your region or country.
Your browser is out of date
With an updated browser, you will have a better Medtronic website experience. Update my browser now.
The content of this website is exclusively reserved for Healthcare Professionals in countries with applicable health authority product registrations, except those practicing in France as some of the content is not in compliance with the French Advertising law N°2011-2012 dated 29th December 2011, article 34.
Click “OK” to confirm you are a Healthcare Professional.
Healthcare Professionals
Pacific Xtreme PTA Balloon Catheter
Percutaneous Transluminal Angioplasty
Treat longer lesions with the Pacific™ Xtreme PTA balloon catheter OTW 0.018" that is offered also in lengths from 150 to 300 mm. These balloons are well suited for use in treating long lesions in the femoral and popliteal vessels.
The Pacific Xtreme is indicated for percutaneous transluminal angioplasty (PTA) in patients with obstructive disease of peripheral arteries, i.e. ilio-femoral-, femoral-, popliteal-, infra-popliteal- and renal arteries.
Pacific Xtreme for carotid and supra-aortic applications
Only balloon catheters with diameters from 2 mm to 7 mm and lengths from 20 mm to 40 mm are indicated for carotid and supra-aortic applications, with the exception of catheters with a usable length of 180 cm.
The Pacific Xtreme PTA catheter is contraindicated for use in coronary arteries. The Pacific Xtreme PTA catheters with diameters from 2 mm to 7 mm and balloon lengths of more than 40 mm with usable lengths of 90 cm and 130 cm are contraindicated for use in carotid and supra-aortic arteries. The Pacific Xtreme PTA catheter with a usable length of 180 cm is contraindicated for use in carotid and supra-aortic arteries.
Instructions for Use
Find this technical manual in the product labeling supplied with each device.
Type | Specification |
---|---|
Catheter Design | Over the wire (OTW), coaxial shaft |
Balloon Material | Flexitec™ Xtreme |
Balloon Coating | LFC hydrophilic |
Balloon Marker | 2 swaged, Platinum Iridium |
Usable Shaft Lengths | 90, 130, 180 cm |
Shaft Diameter | 3.9 F - 4.2 F* |
Guidewire Compatibility | 0.018" |
*Depending on balloon size
Reference Number Usable Length 90 cm |
Reference Number Usable Length 130 cm |
Reference Number Usable Length 180 cm |
Balloon Diameter (mm) |
Balloon Length (mm) |
Recommended Introducer Sheath (F) |
Nominal Pressure (atm) |
RBP (atm) |
---|---|---|---|---|---|---|---|
PCF 040 150 090 | PCF 040 150 130 | PCF 040 150 180 | 4.0 | 150 | 4 | 6 | 14 |
PCF 040 200 090 | PCF 040 200 130 | - | 4.0 | 200 | 4 | 6 | 14 |
PCF 040 250 090 | PCF 040 250 130 | - | 4.0 | 250 | 4 | 6 | 14 |
PCF 040 300 090 | PCF 040 300 130 | - | 4.0 | 300 | 4 | 6 | 14 |
PCF 050 150 090 | PCF 050 150 130 | PCF 050 150 180 | 5.0 | 150 | 4 | 6 | 14 |
PCF 050 200 090 | PCF 050 200 120 | - | 5.0 | 200 | 4 | 6 | 14 |
PCF 050 250 090 | PCF 050 250 130 | - | 5.0 | 250 | 5 | 6 | 14 |
PCF 050 300 090 | PCF 050 300 130 | - | 5.0 | 300 | 5 | 6 | 14 |
PCF 060 150 090 | PCF 060 120 130 | - | 6.0 | 150 | 5 | 6 | 12 |
PCF 060 200 090 | PCF 060 200 130 | - | 6.0 | 200 | 5 | 6 | 12 |
PCF 060 250 090 | PCF 060 250 130 | - | 6.0 | 250 | 5 | 6 | 12 |
PCF 060 300 090 | PCF 060 300 130 | - | 6.0 | 300 | 5 | 6 | 12 |
PCF 070 150 090 | PCF 070 150 130 | - | 7.0 | 150 | 5 | 6 | 12 |
PCF 070 200 090 | PCF 070 200 130 | - | 7.0 | 200 | 5 | 6 | 12 |
PCF 070 250 090 | PCF 070 250 130 | - | 7.0 | 250 | 5 | 6 | 12 |
See product catalogue for complete, detailed product information.
This page may include information about products that may not be available in your region or country. Please consult the approved indications for use. Content on specific Medtronic products is not intended for users in markets that do not have authorisation for use.
Information above is supported by Bench test data which is on file at Medtronic, Inc. Test data is not indicative of clinical performance.
4 F/5 F depending on balloon size