The content of this website is exclusively reserved for Healthcare Professionals in countries with applicable health authority product registrations, except those practicing in France as some of the content is not in compliance with the French Advertising law N°2011-2012 dated 29th December 2011, article 34.
Click “OK” to confirm you are a Healthcare Professional.
Powerful fields produced during MRI have the potential to induce hazardous effects on patients with traditional implantable cardiac devices.
Potential Hazard | Device (Impact) | Field (Static/Gradient/RF) |
---|---|---|
Lead Heating |
Tissue damage may affect pacing or defibrillation therapy. |
RF |
Unintended Cardiac Stimulation |
May lead to a single intermittent stimulation or sustained tachycardia. |
Gradient, RF |
Device Interactions |
CRT, ICD, or pacemaker malfunction or failure may affect pacing or defibrillation therapy. |
Static, Gradient, RF |
Evera MRI™ SureScan system is safe and effective in the MRI environment when MR conditions for use are met.
Advisa MRI™ SureScan system is safe and effective in the MRI environment when MR conditions for use are met.
Ramza B, et al. Are There Cumulative Effects of Multiple MRI on MR-conditional Pacemakers? Presented at HRS, May 2014.
Gold MR, Sommer T, Schwitter J, et al. Full-Body MRI in Patients With an Implantable Cardioverter-Defibrillator: Primary Results of a Randomized Study. J Am Coll Cardiol. June 23, 2015; 65(24):2581-2588.
Shenthar J, Milasinovic G, Al Fagih A, et al. MRI scanning in patients with new and existing CapSureFix Novus 5076 pacemaker leads: randomized trial results. Heart Rhythm. April 2015;12(4):759-765.
Gimbel JR, Bello D, Schmitt M, et al. Randomized trial of pacemaker and lead system for safe scanning at 1.5 Tesla. Heart Rhythm. May 2013;10(5):685-691.
Wilkoff BL, Bello D, Taborsky M, et al. Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment. Heart Rhythm. January 2011;8(1):65-73.