Healthcare Professionals
Reliant Stent Graft Balloon Catheter
EVAR and TEVAR Procedures
You just clicked a link to go to another website. If you continue, you may go to a site run by someone else.
We do not review or control the content on non-Medtronic sites, and we are not responsible for any business dealings or transactions you have there. Your use of the other site is subject to the terms of use and privacy statement on that site.
It is possible that some of the products on the other site are not approved in your region or country.
Your browser is out of date
With an updated browser, you will have a better Medtronic website experience. Update my browser now.
The content of this website is exclusively reserved for Healthcare Professionals in countries with applicable health authority product registrations, except those practicing in France as some of the content is not in compliance with the French Advertising law N°2011-2012 dated 29th December 2011, article 34.
Click “OK” to confirm you are a Healthcare Professional.
Reliant Stent Graft Balloon Catheter
Healthcare Professionals
Reliant Stent Graft Balloon Catheter
EVAR and TEVAR Procedures
Expand possibilities with the Reliant™ stent graft balloon catheter: the versatile, reliable, and conformable solution you need for stent graft procedures and temporary occlusion of the aorta and large vessels.
See the device manual for detailed information regarding the instructions for use, indications, contraindications, warnings, precautions, and potential adverse events. For further information, contact your local Medtronic representative and/or consult the Medtronic Europe website.
The Reliant stent graft balloon catheter is intended to temporarily occlude large vessels or to expand vascular prostheses. The device is intended to assist in the expansion of self-expanding stent grafts.
Reliant Stent Graft Balloon Catheter Features
The Reliant stent graft balloon provides multiple treatments in a single balloon for thoracic, abdominal, and iliac stent graft procedures.
Diameter (mm) |
ml (cc) |
---|---|
10 | 3 |
20 | 9 |
30 | 19 |
40 | 41 |
46* | 60 |
* Maximum inflation diameter
CAUTION: This table is only a guide. Balloon expansion should be carefully monitored under fluoroscopy. Do not exceed maximum inflation diameter (46 mm). Overinflation can cause damage to the vessel wall or stent graft or lead to rupture.
Instructions for Use
Find this technical manual in the Medtronic Manual Library or in the product labeling supplied with each device.
Product Code |
Inflation Diameter (mm) |
Shaft Size (F) |
Working Length (cm) |
Sheath Compatibility (F) |
---|---|---|---|---|
AB46 | 10-46 | 8 | 100 | 12 |
Data on file Medtronic. Maximum of 20 inflations, deflations.