Aortic stent grafts Healthcare professionals

Endurant™ II/IIs Stent Graft System

Endurant IIs stent graft on white background

The Endurant™ family of products provides the standard of care with a legacy of clinical success for the treatment of abdominal aortic aneurysm (AAA). Only the Endurant family of products, designed to address sac regression,1 has the deep clinical experience, favorable outcomes, and the most validated data on any single graft for everyday or extraordinary challenges. For the past five years, the Endurant II/IIs has been used in 1 out of 3 EVAR cases,1 with use in more than 450,000 patients worldwide.1

Indications, Safety, and Warnings

Product Details

RadiantTM Balloon-Expandable Covered Stent

Radiant balloon-expandable covered stent on transparent background

The only covered stent indicated for ChEVAR, Radiant™ covered stent is used in combination with the Endurant II/IIs stent graft system to safely and effectively lengthen aortic proximal sealing zones in juxtarenal aortic abdominal aneurysms (jAAA).  

Indications, Safety, and Warnings

Product Details

ValiantTM Thoracic Stent Graft with the CaptiviaTM Delivery System

Valiant Thoracic stent graft with the Captivia delivery system wrapped around the covered stent graft on a white background

Select the Valiant thoracic stent graft with the Captivia delivery system for your TEVAR (thoracic endovascular aortic repair) procedures.

Proven design and performance offer a broad set of options to treat a wide range of patient anatomies. With more than 100,000 patients treated worldwide, the Valiant Captivia stent graft system is designed to treat all lesions of the descending thoracic aorta, including thoracic aortic aneurysms (TAA), type B aortic dissection (TBAD), intramural hematoma (IMH), penetrating atherosclerotic ulcer (PAU), and blunt thoracic aortic injury (BTAI).

Indications, Safety, and Warnings

Product Details

Urgent Medical Device Recall
Valiant Navion Thoracic Stent Graft System

Valiant Navion FreeFlo graft deploying from delivery system on white background
  Product Details

Heli-FXTM EndoAnchorTM System

Heli-FX EndoAnchor system including deflecting guide catheter with cassette containing EndoAnchors

Provide transmural fixation of the endograft to the aorta with the Heli-FX EndoAnchor system. The Heli-FX EndoAnchor system enhances durability to the level of a surgical anastomosis and addresses concerns for future complications.

Indications, Safety, and Warnings

Product Details

ReliantTM Stent Graft Balloon Catheter

Reliant stent graft balloon catheter on white background

Expand possibilities with the Reliant stent graft balloon catheter: the versatile, reliable, and conformable solution you need for stent graft procedures and temporary occlusion of the aorta and large vessels.

Indications, Safety, and Warnings

Product Details

TourGuideTM Steerable Sheath

TourGuide steerable sheath illustrating the 180-degree deflection with curve retention and radiopaque tip

Precisely guide your next intervention with the TourGuide steerable sheath. The sheath can deflect up to 180° to facilitate the delivery of diagnostic and therapeutic devices to a wide variety of vessel takeoffs and challenging anatomical areas.

Indications, Safety, and Warnings

Product Details

SentrantTM Introducer Sheath

Sentrant introducer sheath with hydrophilic coating

Achieve superior seal and tracking in straightforward and complex anatomies with the Sentrant introducer sheath.

Indications, Safety, and Warnings

Product Details
*

Third-party brands are trademarks of their respective owners.

Bench test data on file with reference UC201607697cIE Tour Guide Claims Matrix. Test data not indicative of clinical performance.

Bench test data on file with reference UC201301442bEN Sentrant Claims Matrix. Test data not indicative of clinical performance. Bench test compared Cook Check-Flo™* Performer™* and Gore DrySeal™* 12 F and 18 F to Sentrant 12 F and 18 F.

Reference

1

Data on file with reference Endurant Brand deck MARKETING CLAIMS MATRIX 1.22.2020.