Oxygenation System
The Affinity Pixie™ Oxygenation System delivers performance and versatility for neonates, infants and small children requiring cardiopulmonary bypass at flow rates up to 2.0 L/minute. Its comprehensive system design offers ease of setup, ease of use, and minimised prime volumes.
The system features the Affinity Orbit™ Holder System, which provides even greater device positioning flexibility to adapt to your preferred circuit setup.
Two biocompatible surface options are provided for the oxygenator and cardiotomy/venous reservoir:
Advanced Affinity™ Oxygenator Technology in a compact, low-prime design
This paediatric oxygenator features:
Ergonomic, easy-to-use design. Minimised blood contact with antifoam
This paediatric cardiotomy/venous reservoir features:
Affinity Orbit™ Holder System
Quick setup. Custom device positioning and orientation
Affinity™ Manifold Holder
Affinity™ Manifold Holder System
This is an image of the Affinity Orbit™ holder system for use with the Affinity Pixie™ oxygenation system.
Affinity Manifold™ Holder System
Caution: For a complete listing of indications, contraindications, precautions and warnings, please refer to the Instructions for Use which accompany each product.
Order NumberCBP211 | DescriptionHollow Fiber Oxygenator with Cortiva™ BioActive Surface | # of UnitsTubing packs only |
Order NumberBBP211 | DescriptionHollow Fiber Oxygenator with Balance™ Biosurface | # of UnitsTubing packs only |
Order NumberCBP241 | DescriptionHollow Fiber Oxygenator and Cardiotomy/Venous Reservoir with Cortiva BioActive Surface | # of UnitsTubing packs only |
Order NumberBBP241 | DescriptionHollow Fiber Oxygenator and Cardiotomy/Venous Reservoir with Balance Biosurface | # of Units4 per case |
Order Number ATP210 |
Description Affinity™ Temperature Probe |
# of Units 1 per case |
Order Number AUH2093 |
Description Affinity Orbit™ Holder System |
# of Units 1 per case |
Order Number AMH2014 |
Description Affinity™ Manifold Holder |
# of Units 1 per case |
Balance™ is a registered trademark of Medtronic. Technology licensed under agreement from BioInteractions, Limited, United Kingdom.
See chart below.
Comparison between Balance-coated and uncoated in vitro bench test circuits of percentage of platelets that are activated with adenosine diphosphate (ADP @20 μM) in circulating heparinized human blood over time. Error bars represent standard deviation. († indicates p < 0.05)
Warnings: A strict anticoagulation protocol should be followed and anticoagulation should be routinely monitored during all procedures. The benefits of extracorporeal support must be weighed against the risk of systematic anticoagulation and must be assessed by the prescribing physician.
Caution: For a complete listing of indications, contraindications, precautions and warnings, please refer to the Instructions for Use which accompany each product.