The content of this website is exclusively reserved for Healthcare Professionals in countries with applicable health authority product registrations, except those practicing in France as some of the content is not in compliance with the French Advertising law N°2011-2012 dated 29th December 2011, article 34.
Click “OK” to confirm you are a Healthcare Professional.
for atherectomy of peripheral vasculature
Treat above and below the knee with the HawkOne™ Directional Atherectomy System to restore blood flow by removing plaque in patients with peripheral arterial disease (PAD).
The HawkOne™ device treats all plaque morphologies, including severe calcium. Quick and easy cleaning makes your procedure efficient. If your treatment goal is to make a small channel or to maximize luminal gain, choose HawkOne™ to preserve a patient's native vessel and keep future treatment options open.
Animation: HawkOne mechanism of action video - (01:55)
Animation about the functioning of HawkOne, Directional Atherectomy SystemHawkOne, mechanism of action, animation, UC202401621-hawkone-mechanism-of-action-animation-en-we-9751563, UC202401621EE, UC202401621
More information (see more)
Less information (see less)
The HawkOne™ Directional Atherectomy System is intended for use in atherectomy of the peripheral vasculature. The HawkOne™ catheter is indicated for use in conjunction with the SpiderFX™ Embolic Protection Device in the treatment of severely calcified lesions. The HawkOne™ catheter is NOT intended for use in the coronary, carotid, iliac, or renal vasculature.
Preloaded distal flush tool
Drive shaft
Cutter blade
Instructions for Use
Find this technical manual in the product labeling supplied with each device or by calling technical support for cardiovascular devices: +1 763-526-7890.
|
7 F |
7 F |
6 F |
6 F |
---|---|---|---|---|
Model name |
LS |
LX |
M |
S |
Catalog number |
H1-LS-INT |
H1-LX-INT
|
H1-M-INT
|
H1-S-INT
|
Vessel diameter (mm) |
3.5–7.0 |
3.5–7.0 |
3.0–7.0 |
2.0–4.0 |
Sheath compatibility (Fr) |
7 |
7 |
6 |
6 |
Crossing profile (mm) |
2.6 |
2.6 |
2.2 |
2.2 |
Working length* (cm) |
114 |
114 |
135 |
151 |
Effective length† (cm) |
107 |
104 |
129 |
145 |
Tip length (cm) |
6.6 |
9.6 |
5.9 |
5.9 |
Max. cut length (mm) |
50 |
75 |
40 |
40 |
Packing device |
X |
X |
X |
X |
*Working length — Distal end of preloaded flush tool, in the proximal position, to the distal end of tip.
†Effective length — Distal end of preloaded flush tool, in the proximal position, to the proximal end of cutter window.
Choose from a full portfolio of peripheral products for endovascular interventions — products that help you reach your PAD patient treatment goals.
CardioVascular Lifeline Customer Support
24-hour technical support
Data on file. HawkOne 6F Tissue Embolization and Removal Consistency, Mass Per Mass, and Cut Depth Report (RE-PV15259).
HawkOne 7F Bench Performance Verification Testing, Embolization (RE-PV13728).
HawkOne 6F Design Validation Cadaver Report (10542060DOC).
HawkOne 7F Design Validation Cadaver Report (RE-PV13727).
Refer to IFU for instruction for treating severe calcium.