OsteoCoolTM 

 

Radiofrequency Ablation System

The OsteoCoolTM RF Ablation System is cooled radiofrequency (RF) ablation technology. It offers simultaneous, dual-probe capabilities for treating painful bone tumors.

About the therapy

Overview

INDICATIONS

  • Palliative treatment in spinal procedures by ablation of metastatic malignant lesions in a vertebral body.
  • Coagulation and ablation of tissue in bone during surgical procedures including palliation of pain associated with metastatic lesions involving bone in patients who have failed or are not candidates for standard therapy.
  • Ablation of benign bone tumors such as osteoid osteoma.

LIVE CASE FILMING & TECHNOLOGY DISCUSSION

Watch a periacetabular ablation procedure with discussion by Dr. Julien Garnon.

PRODUCT DETAILS

Image from breast cancer case study with Dr. Levy.

Image courtesy of Dr. Jason Levy

The OsteoCool RF Ablation system is cooled radiofrequency (RF) ablation technology. It offers simultaneous, dual-probe capabilities for treating painful bone tumors.

Coaxial, bipolar technology delivers RF energy to the site, and automatically moderates power to keep RF heating within the desired treatment range. This reduces risk of potential thermal damage to adjacent tissue.1

The active tip of the ablation probe is internally cooled with circulating water. RF energy heats the tissue while circulating water moderates the temperature close to the active tip. This combination:

  • Creates large volume lesions without excessive heating at the active tip
  • Minimizes potential for char

The OsteoCool RF ablation probes are sterile and intended for single use.

DOWNLOAD THE OSTEOCOOL BROCHURE

CUSTOMIZE YOUR ABLATIONS OPTIONS

OsteoCool can be utilized using one probe or two probes.

You’ll find flexibility with a wide range of ablation scenarios for your patient and procedural needs:

  • Metastatic and benign bone tumor ablation
  • Simultaneous ablation of adjacent or multiple levels in the spine
  • Simultaneous ablation using two probes, such as bipedicular spine tumor ablation
  • Ablation using one probe
  • Multiple active tip sizes and introducer gauge options
  • Custom ablation zones
  • Track ablation

Risks

  • As a consequence of electrosurgery, damage to surrounding tissue through iatrogenic injury could result
  • Pulmonary embolism
  • Nerve injury including thermal injury, puncture of spinal cord or nerve roots potentially results in radiculopathy, paresis, and paralysis

The OsteoCoolTM RF Ablation bone access kits are indicated for percutaneous access to bone.

 

Contact us for more information

*Indicates Required Field

Your information will be processed and protected in accordance with our privacy statement

Selecting “no” to marketing emails above will not affect your other email selections, and a Medtronic representative will still reach out via email, if selected. Your personal data will used to manage your relationship with Medtronic, and, if you consent, to provide you with relevant email updates based on your user preferences. You can opt-out of receiving such emails at any time by clicking the unsubscribe link in the relevant email. Medtronic may use pixels and other technologies in emails to gather statistics around email opening and clicks, to help us improve our communications and to provide you with relevant content. For more information, see the Medtronic privacy notice.

You can always change your preferences or update your personal details by visiting the Preference center.

See the Preference center

1

Based on internal testing. Data on file.

See the device manual for detailed information regarding the instructions for use, indications, contraindications, warnings, precautions, and potential adverse events. For further information, contact your local Medtronic representative and/or consult the Medtronic website at medtronic.eu

The views and opinions of the HCP expressed therein should be interpreted as personal views. They are completely independent and do not necessarily reflect the opinions of Medtronic.