Micra™AV2 leadless pacemaker

Micra™ AV2 is a VDD lealdless pacemaker that provides atrioventricular (AV) synchrony for bradycardia patients.

Overview

Micra™ AV2 is a VDD leadless pacemaker with automatic AV synchrony to treat patients with bradycardia. This device is delivered percutaneously via a minimally invasive approach and does not require the use of leads.​

Micra™ AV2 devices are implanted with the same streamlined procedure as previous Micra™ devices.​

Micra AV2 features

battery icon

Increased battery longevity

The projected median longevity is nearly 16 years, which means more than 80% of patients only need one Micra™ device for life.1​

synchrony icon

Smarter AV synchrony
 

The improved algorithms on Micra™ AV2 automatically customize AV synchrony settings for each patient, reducing the need for manual programming by more than 50% compared to Micra™ AV.​1

The smarter algorithms also improve automatic AV synchrony at faster heart rates between 80–100 bpm1, and the upper tracking rate limit is now 135 bpm.​

delivery icon

Enhanced delivery system


The updated delivery system now has a rounded catheter tip with more surface area to decrease tip pressure during device implant.2

Model specifications

Parameter

Micra AV2

Pacing mode

VVI, VVIR, VOO, OVO, VDD, VDI, ODO, OFF

Mass

1.75 g

Volume

0.8 cc

Electrode spacing

18 mm

Battery longevity

15.6 years1

Accelerometer-based mechanical atrial sensing

Yes

Accelerometer-based rate response

Yes

MRI SureScan

≤ 3T

CareLink remote monitoring

Yes

 

Discover the next generation of the world’s smallest pacemakers4

Micra™ AV2 and Micra™ VR2

Micra AV2 VR2

Micra™ clinical evidence

Request more information

Educational resources on Medtronic Academy

Access interactive courses, videos, and educational resources to extend your knowledge on Micra™.

References

1

Sheldon T, Escalante K, Fagan D. Device Longevity and AV Synchrony Algorithm Modeling of a Leadless Pacemaker Family: A Virtual Patient Analysis. January 2023. Medtronic data on file.

2

Roberts PR et al, Preclinical cardiac perforation reduction in leadless pacing: An update to the Micra leadless pacemaker delivery system. Pacing Clin Electrophysiol. 2023 Sep;46(9):1085-1091.

3

Williams E, Whiting J. Micra Transcatheter Pacing System Size Comparison. November 2014. Medtronic data on file.

4

Nippoldt D, Whiting J. Micra Transcatheter Pacing System Device Volume Characterization Comparison. November 2014. Medtronic data on file.

CE mark 0123
CE mark 0344