Your browser is out of date

With an updated browser, you will have a better Medtronic website experience. Update my browser now.

×

Skip to main content

Healthcare Professionals

MRI SureScan Pacing Leads

for Bradyarrhythmia Management

Meeting the need for pacing and MRI

Worldwide, it is estimated that up to 75% of patients with implanted cardiac devices will need an an MRI scan during the lifetime of their device.1 The following five SureScan pacing lead options allow patients to undergo an MRI under specific conditions for use when used in combination with a SureScan cardiac device.

  • SelectSecure™ MRI SureScan™ Model 3830
  • CapSureFix Novus MRI SureScan Models 5076, 4076
  • CapSure Sense MRI SureScan Models 4074, 4574

SelectSecure MRI SureScan Model 3830

SelectSecure MRI SureScan Model 3830 is a reliable thin and catheter delivered lead. For conduction system pacing, it can be used with the SelectSite™ catheter C304 (C304S59:30 cm, C304L69:40 cm, C304XL74:45 cm and C304-HIS) or the C315 catheter. It is CE approved to be used for pacing and sensing at the Bundle of His or in the left bundle branch area, as an alternative to right ventricular pacing in a single or dual chamber pacing system.

Note: the lengths 49, 98 and 110 cm are not MRI compatible.

CapSureFix Novus MRI SureScan Model 5076, 4076

The electrically active helix of the SureScan Model 5076 and 4076 leads are designed to extend easily for active fixation and retract for venous passage.

The CapSureFix Novus MRI SureScan Model 5076 was the second pacing lead to be approved for use in the MRI environment. More than 3.2 million of these leads have been sold worldwide with 97.6% reliability at 10 years.2,3

CapSure Sense MRI SureScan Models 4074, 4574

The CapSure Sense MRI SureScan, steroid-eluding leads with a ring-shaped tip and titanium nitride (TiN) microstructure are designed for optimal sensing and system performance resulting in better detection of ventricular capture.

Active Fixation

Lead 3830

SelectSecure MRI SureScan Pacing and Sensing Lead

Download Spec Sheet - Model 3830

Passive Fixation

CapSure Sense MRI SureScan pacing and sensing lead

CapSure Sense MRI SureScan

Download Spec Sheet - Models 4074 & 4574

1

Kalin R, et al. Pacing Clin Electrophysiol. 2005;28:326-328.

2

Vogl H. Total Sales of Sprint Quattro ICD Leads and 5076 pacing leads. Medtronic data on file. November 18, 2014.

3

DeBus B. Model 5076 Lead Survival Function Calculation. Medtronic data on file. August 2014.

CE mark 0123