Bio-Medicus NextGen cannulae for cardiac surgery
Bio-Medicus™ NextGen cannulae are available in femoral venous, femoral arterial, and jugular venous configurations. All NextGen cannulae are engineered for smooth transitions and ease of insertion. They feature more than 30 enhancements to the original Bio-Medicus cannulae.
Download brochureOverview
Indications
Bio-Medicus NextGen devices are to be used by a trained physician only. Cannulae are used to cannulate vessels, perfuse vessels or organs, and/or connect with accessory extracorporeal equipment. The cannula introducer is intended to facilitate proper insertion and placement of the appropriate sized cannula within the vessel for cardiopulmonary bypass. These products are intended for use up to six hours or less.
Product details
Femoral arterial/jugular venous cannulae
Jugular venous
- Intended for internal jugular venous usage
- Traditional femoral arterial insertion achieves high flow rates with minimal pressure differential2
- Cannula
- Internal jugular venous position offers enhanced return with high pressure flow rates and minimal pressure differential2
New
Multi-stage femoral venous cannulae
- Designed for easy placement across the atrium during MICS procedures
- Advanced multi-stage design optimizes drainage of the entire circulation by accessing the IVC, atrium, and SVC
- Traditional IVC/atrial junction position promotes efficient venous drainage
Bi-caval femoral venous cannulae
- Bi-caval capability with optimized basket placement
- Designed to enable right atrium occlusion and access — 27 Fr and 29 Fr models
Pediatric arterial and venous
- Arterial or venous cannula, hemostasis cap, adjustable radiopaque suture ring
- Tapered solid-core and percutaneous-style introducer
- Cannula/tubing retention clip
Pediatric arterial
- Tapered percutaneous-style 0.025 mm guidewire
Pediatric venous
- Reinforced side holes support smooth insertion1
Key features
Femoral arterial/internal jugular venous cannulae
Bio-Medicus NextGen cannulae offer ease of insertion and are engineered for smooth transitions. Fingerlet supports are formed into the tapered tip to create a smooth transition between the introducer and the thin cannula wall. All of these advanced Bio-Medicus cannulae design features add up to your opportunity for a smooth insertion.
Hemostasis management — the right fit
Our cap and introducer design for all NextGen cannulae offers improved function. The increased friction fit between cap and introducer helps prevent backing out when inserting or advancing in the vessel.1 The introducer hub’s smaller guidewire opening also equates to a reduction in blood loss.1
- Repositionable suture ring is radiopaque1
- Friction fit hemostasis cap
- Vented standard 3/8 inch connector
- Shorter clamp site eases tubing management
New
Multi-stage femoral venous cannulae
- Depth markings allow for visualizing the introducer's length beyond the tip of the cannula body
- Tip taper location indicator
- 3/8 inch nonvented connector
- Echo-friendly cannula body design1
- Elongated taper allows introducer to dilate the vessel over a longer distance during insertion
- Overall tip length up to 60 cm
- Efficient tracking1: long-tapered introducer facilitates placement
- Smooth transitions1: tapered tip design
- Enhanced drainage: six large tip side holes
- Easy insertion and removal1: smooth side holes
- Marker band: indicates that all side holes are inserted at minimum depth within vessel
- Flexible and kink-resistant2: stainless-steel wirewinding and reinforced side-hole baskets
Femoral bi-caval venous cannulae
- Elongated taper on bi-caval venous cannula models offers dilation over a longer distance
- Introducer markings confirm alignment of cannulae and introducer tip
- One-piece non-phthalate PVC introducer with elongated taper
- No-step transition zone promotes easy insertion1
- Smooth side-hole port design for easy insertion1
- Thin-wall design promotes maximum flow rates1
- Fingerlet reinforced tip design offers ease of insertion1
- Flexible and kink-resistant,2 stainless-steel wirewinding and reinforced baskets
Flow performance
Compare the pressure drop to the arterial line flow.
Femoral arterial2
Pressure drop vs. flow
Internal jugular venous2
Pressure drop vs. flow
Venous multi-stage2
Pressure drop vs. flow
Bi-caval venous2
Pressure drop vs. flow
Pediatric arterial2
Pressure drop vs. flow
Pediatric venous2
Pressure drop vs. flow
Model specifications
You can order Bio-Medicus NextGen adult-size cannulae as individual units or kits. You may order insertion kits separately for pediatric and adult cannulae. See our brochure for complete, detailed product information.
Bio-Medicus NextGen femoral arterial/jugular venous cannulae
- 3/8 in (0.95 cm) vented connector
- One unit per carton
Cannula model |
Kit model |
French size |
Overall length |
Tip length |
---|---|---|---|---|
96570-115 |
96530-115 |
15 Fr (5.0 mm) |
31.8 cm |
18.0 cm |
96570-117 |
96530-117 |
17 Fr (5.7 mm) |
31.8 cm |
18.0 cm |
96570-119 |
96530-119 |
19 Fr (6.3 mm) |
31.8 cm |
18.0 cm |
96570-121 |
96530-121 |
21 Fr (7.0 mm) |
31.8 cm |
18.0 cm |
96570-123 |
96530-123 |
23 Fr (7.7 mm) |
31.8 cm |
18.0 cm |
96570-125 |
96530-125 |
25 Fr (8.3 mm) |
31.8 cm |
18.0 cm |
Bio-Medicus NextGen multi-stage femoral venous cannulae
- 3/8 in (0.95 cm) non-vented connector
- One unit per carton
Cannula model |
Kit model |
French size |
Overall length |
Tip length |
---|---|---|---|---|
96670-115 |
96600-115 |
15 Fr (5.0 mm) |
64.8 cm |
50.0 cm |
96670-117 |
96600-117 |
17 Fr (5.7 mm) |
64.8 cm |
50.0 cm |
96670-119 |
96600-119 |
19 Fr (6.3 mm) |
69.9 cm |
55.0 cm |
96670-121 |
96600-121 |
21 Fr (7.0 mm) |
69.9 cm |
55.0 cm |
96670-123* |
96600-123* |
23 Fr (7.7 mm) |
76.2 cm |
60.0 cm |
96670-125* |
96600-125* |
25 Fr (8.3 mm) |
76.2 cm |
60.0 cm |
*1/2 in (1.27 cm) to 3/8 in (0.95 cm) tubing adapter included with venous models 23 Fr and 25 Fr models.
Femoral bi-caval venous cannulae
Cannula model |
Kit model |
French size |
Overall length |
Tip length |
---|---|---|---|---|
96670-127* |
96600-127 |
27 Fr (9.0 mm) |
76.2 cm |
60.0 cm |
96670-129* |
96600-129 |
29 Fr (9.7 mm) |
76.2 cm |
60.0 cm |
*1/2 inch (1.27 cm) to 3/8 inch (0.95 cm) tubing adapter included.
Bio-Medicus NextGen pediatric arterial cannulae with introducers
- 1/4 in (0.64 cm) non-vented connector
- One unit per carton, 22.9 cm overall length
Model |
French size |
Tip length |
---|---|---|
96820-108 |
8 Fr (2.7 mm) |
10.0 cm |
96820-110 |
10 Fr (3.3 mm) |
10.5 cm |
96820-112 |
12 Fr (4.0 mm) |
11.0 cm |
96820-114 |
14 Fr (4.7 mm) |
11.5 cm |
Bio-Medicus NextGen pediatric venous cannulae with introducers
- 1/4 in (0.64 cm) non-vented connector
- One unit per carton, 22.9 cm overall length
Model |
French size |
Tip length |
---|---|---|
96830-108 |
8 Fr (2.7 mm) |
10.0 cm |
96830-110 |
10 Fr (3.3 mm) |
10.5 cm |
96830-112 |
12 Fr (4.0 mm) |
11.0 cm |
96830-114 |
14 Fr (4.7 mm) |
11.5 cm |
Bio-Medicus NextGen insertion kits
Five units per carton
Model |
Style |
---|---|
96551 |
Venous |
96552 |
Arterial/jugular |
96553 |
Pediatric arterial/venous |
Additional resources
EMEA cannulae catalog
Find your ideal cannulae for the extracorporeal, cardioplegia, or suction circuit, as well as surgical support products.
Extracorporeal cannulae guides
Important safety information
See the device manual for detailed information regarding the instructions for use, indications, contraindications, warnings, precautions, and potential adverse events. For further information, contact your local Medtronic representative.
For applicable products, consult instructions for use on www.medtronic.com/manuals. Manuals can be viewed using a current version of any major internet browser. For best results, use Adobe Acrobat® Reader with the browser.
This information is intended only for users in markets where Medtronic products and therapies are approved or available for use as indicated within the respective product manuals. Content on specific Medtronic products and therapies is not intended for users in markets that do not have authorization for use.
References
Medtronic data on file.
Bench data on file, may not be indicative of clinical performance.