Lower irrigation flow rate is required as minimal heat is retained at the catheter tip.
During the ablation process, the tissue surface temperature is measured in real-time, 50 times per second. Ablation power is automatically adjusted to match the ablation set temperature.
A 1.1 mm high-resolution electrode (HRE) at the tip allows for the recording of highly localized EGMs at the center of ablation with minimal far-field artifact2
Align the center of ablation with the center of mapping with a close bipolar catheter tip configuration
Details
7.5 Fr, open-irrigated catheter
4.1 mm catheter tip segment
6 externally placed temperature-sensing thermocouples,
Dual composite tip electrode
2 ring electrodes
6 irrigation ports
Includes customized offerings:
Small and large curve configurations
Unidirectional and bidirectional models
1 min 42 seconds
More information (see more)
Less information (see less)
1 min 14 seconds
More information (see more)
Less information (see less)
1 min 3 seconds
More information (see more)
Less information (see less)
1 min 41 seconds
More information (see more)
Less information (see less)
1 min 8 seconds
More information (see more)
Less information (see less)
1 min 2 seconds
More information (see more)
Less information (see less)
Visit Medtronic Academy
Important reminder: This information is intended only for users in markets where Medtronic products and therapies are approved or available for use as indicated within the respective product manuals. Content on specific Medtronic products and therapies is not intended for users in markets that do not have authorisation for use.
See the device manual for detailed information regarding the instructions for use, indications, contraindications, warnings, precautions, and potential adverse events. For further information, contact your local Medtronic representative and/or consult the Medtronic website at www.medtronic.eu.
For applicable products, consult instructions for use on manuals.medtronic.com. Manuals can be viewed using a current version of any major internet browser. For best results, use Adobe Acrobat® Reader with the browser.
Kautzner J, Albenque JP, Natale A, et al. A Novel Temperature-Controlled Radiofrequency Catheter Ablation System Used to Treat Patients With Paroxysmal Atrial Fibrillation. JACC Clin Electrophysiol. March 2021;7(3):352-363.
Avila C. DiamondTemp Catheter Design. Medtronic data on file, January 2021.
Verma A, Schmidt MM, Lalonde JP, Ramirez DA, Getman MK. Assessing the Relationship of Applied Force and Ablation Duration on Lesion Size Using a Diamond Tip Catheter Ablation System. Circ Arrhythm Electrophysiol. July 2021;14(7):e009541.
Iwasawa J, et al. Temperature-controlled radiofrequency ablation for pulmonary vein isolation in patients with atrial fibrillation. J Am Coll Cardiol. 2017;70:542-553.
Neuzil P et al. The FASTR-AF Trial: Assessing the Diamond Tip temperature-controlled radiofrequency ablation catheter to treat patients with Atrial Fibrillation. Heart Rhythm, Volume 18, Issue 8, Supplement, S401, August 2021